Wireless Datalogger - Model 8026
The Model 8026 Wireless Datalogger is intended to transmit data from buried sensors installed in inaccessible locations. It’s designed around the Campbell Scientific, Inc. Model CR800 Datalogger, specifically to read Geokon’s line of Vibrating Wire sensors. The 8026 Datalogger is housed in a rugged enclosure (standard enclosure is PVC, optional stainless steel enclosure also available) together with a D-cell lithium battery pack (for unattended operation) and an RF modem (for wireless data transmission). It has low power consumption, wide temperature range and is moisture resistant. It’s configured to read 6 sensors; either 6 VW or 3 VW plus 3 thermistors, or any combination thereof. The 8026 is typically installed with a Spread Spectrum Radio Modem and Antenna.
Specifications
Range: ±2.5 millivolts to ±5 volts (analog)
DC to 200 kHz (frequency)
Resolution: 0.33 microvolts to 1333 microvolts (analog)
±35 nS/no. cycles measured (frequency)
Accuracy: ±0.1% F.S. of reading, plus offset (analog)
±0.01% of reading, plus resolution (frequency)
Excitation Output: ±2.5 V at 25 mA (maximum),
Frequency Sweep 5 V with AVW200
Battery: 4 × D cell Lithium 8.5 Ah
Temperature Range: −25°C to +50°C (−55°C to +80°C optional)
Diameter × Height: 168 × 381 mm
Geokon, Incorporated, 48 Spencer Street, Lebanon, New Hampshire, 03766 · USA. Tel.: 1(603)448-1562, FAX: 1(603)448-3216, e-mail: info@geokon.com