Your single point of reference for all your Geotechnical Inquiries

Autoresonant Piezometer (VW)-Model 4500AR

The Model 4500AR “Autoresonant” Piezometer is designed for use with existing data acquisition systems incapable of reading standard (pluck and read) vibrating wire sensors. It can also be used where low frequency (< 20 Hz) dynamic measurements are required. Power comes from a 6-24 VDC supply, which yields a 5 V square wave output at the sensor frequency. This high-output offers excellent noise immunity and enhanced signal transmission over long (300 m+) cables. The Model 4500AR is available in standard pressure ranges, with corresponding resolution, linearity and accuracy.
Specifications
Standard Ranges    7, 17, 35, 70, 170, 350, 700 kPa;
                                 1, 2, 3, 5, 7.5, 10, 20, 25, 35, 50, 75, 100, 150 MPa
Over Range    2 × rated pressure
Resolution¹    0.025% F.S. (minimum)
Accuracy        ±0.1% F.S.
Linearity        <0.5% F.S. (±0.1% F.S. optional)
Temperature Range²    −20°C to +80°C
Length × Diameter    varies according to pressure range


Contact:

Geokon, Incorporated, 48 Spencer Street, Lebanon, New Hampshire, 03766 · USA. Tel.: 1(603)448-1562, FAX: 1(603)448-3216, e-mail: info@geokon.com

Country:
USA
User Rating:
You must be registered to vote.